ICX-510 incl ICX-AlphaCom Core

The ICX-510-IA Intelligent Communication Gateway connects people, devices, and systems at unprecedented levels of manageability, scalability, robustness, and interoperability.
ICX-510-IA will provide your site with all your communication needs as it is easy to extend in functionality and system size, and is designed to be future-proof. The system can be tailored to support applications of almost unlimited specificity and complexity.
Zenitel’s ICX (Intelligent Communications X) implies the deployment of VoIP applications required in critical situations. ICX-510-IA provides carrier-class system availability and protects resources in an IP environment by using embedded security mechanisms.
The main security mechanisms used are hardware Root of Trust, software integrity check (SHA256), restricted management access, separate management interface, and internal firewall.
For more information on ICX-510-IA please see Zenitel Wiki
| MECHANICAL & ENVIRONMENTAL | |||
|---|---|---|---|
| Dimensions (WxHxD) | 162 x 44.5 x 200 mm / 6.38 x 1.75 x 7.87 inches | ||
| Weight | 1 kg / 2.2 lbs | ||
| Power | Nominal 24VDC – 48VDC, 15 W (min/max: 20VDC-63VDC) | ||
| Mounting | Wallmount or 19” rack | ||
| Processor subsystem | NXP LS1043 | ||
| Storage subsystem | Solid state (4048 MB Flash). MicroSD, USB | ||
| Temperature Range | -15°C to +55°C / 5°F to 131°F | ||
| Relative Humidity | 95% |
| FEATURES | |||
|---|---|---|---|
| Memory | 4048 MB SDRAM, 4048 MB NAND Flash, 128 MB NOR Flash | ||
| Subscriber Capacity | 552 intercom stations per server | ||
| Busy Hour Call | 60 000 BHCA | ||
| Network ports | High speed, up to 1 gigabit per second | ||
| Software Integrity Check | SHA256 | ||
| IP Priority | DiffServ, IP TOS | ||
| IP Security | Hardware root of trust, SSH, HTTPS, firewall | ||
| SIP | RFC 3261, SIP INFO, RE-Invite. RFC 2833, RFC 4733, | ||
| VoIP Internal Networking | 64 channels | ||
| VoIP External Networking | 64 channels | ||
| ISDN Trunk | ISDN PRI (30 channels); VoIP external networking + gateway | ||
| Analog Trunk | FXO (4 & 8 channels); VoIP external networking + gateway | ||
| GSM Trunk | Quad band GSM; VoIP external networking + gateway | ||
| Other | Vingtor-Stentofon Data scripting engine (EDIO) | ||
| VoIP Audio | HD Audio – 16 kHz (background music, see additional information on the Zenitel wiki), HD Voice – G.722 (7 KHz), Telephone Audio – G.711 (3.4 KHz) | ||
| Configuration | AlphaPro over IP, Web | ||
| Monitoring and Logging | SNMP trap, SNMP MIB, syslog, Web, e-mail, SqLite | ||
| SW Upgrade | System recovery upgrade via SD-card, Web, Automatic upgrade of IP station | ||
| Open Duplex Conference | 20 open duplex conferences can be configured. A maximum of 16 subscribers can participate in 1 conference but maximum 64 subscribers can participate divided over multiple channels simultaneously. | ||
| Push-to-Talk Conference | 50 conference channels. Unlimited number of participants. Priority features | ||
| Group Call | 250 groups. Unlimited number of participants. Priority features | ||
| Call Modes | Open mode. Ringing mode. Call request mode. Priority features | ||
| Audio Messaging | PA broadcasting. Auto-attendant, Voice guidance (doors, elevators), Security voice response | ||
| Compliance | CE, FCC Part 15 | ||
| Certifications | IEC/UL62368-1, EN61000-6-X, EN60945, EN 50121-4; In order to comply with UL safety requirements, the unit has to be supplied by a power supply specified as a Limited Power Source (LPS) or PS2 (cased on IEC/UL 62368-1 definition) or NEC Class 2 source of supply |
| CERTIFICATIONS | |||
|---|---|---|---|
| EMC | IEC/EN 61000-6-2 Industrial Immunity | ||
| IEC/EN 61000-6-4 Industrial Emissions | |||
| IEC/EN 61000-6-1 Light Industrial Immunity | |||
| IEC/EN 61000-6-3 Light Industrial Emission | |||
| EN 55032 class B Multimedia equipment | |||
| Maritime | IEC/EN 60533 Maritime | ||
| IEC/EN 60945 | |||
| Vibration | 2Hz-100Hz (IEC/EN 60068-2-6) | ||
| Dry heat | 55°C (131°F) (IEC/EN 60068-2-2) | ||
| Low Temperature | -15°C (5°F) (IEC/EN 60068-2-2) | ||
| Damp Heat, Cyclic | 40°C (104°F) / 93%RH (IEC/EN 60068-2-2) | ||
| Safety | UL62368-1 certification | ||
| CB certification to IEC62368-1 |