The Intelligent Noise Sensor is a rugged, robust VoIP device designed for open areas and industrial locations. Powered by PoE/24VDC, the INS-002 has ruggedised connectors for external microphones and/or speakers depending on the scenario.Â
The modular design provides versatility to function as either an ambient noise sensor and/or as a public address end-point providing a VoIP solution that can be connected to a wider TCP/IP/SIP based network. By continuously reporting ambient noise levels to a server or an SCA end-point device, reactionary audio zones can be added to an intercom/PA system.
SCA end-point devices boast Automatic Volume Control (AVC) algorithms utilising one or several INS-002’s per audio zone reacting to ambient noise levels. Speaker output gain and the Sound Pressure Levels (SPL) at public address end-points fluctuate depending on the ambient levels at the INS-002(s). This allows loud and clear public address announcements to be made in variable environments.
AUDIO
| Codecs | G.711, G.722, G.729 |
| Noise Cancelling: musical noise suppression | Yes |
| Automatic Volume Control (AVC) | Yes |
| Acoustic Echo Cancellation (AEC) | Yes |
| Frequency Range, G.722 Codec | 200 Hz – 7000 Hz |
| Internal Speaker Amplifier | 10 W class D |
HARDWARE
| LED Indication | External blue LED for operational status |
| Power Consumption | Idle: 3W, max: 12.9W (depending on output volume) |
| Connectors | 1 x industrial rugged RJ-45 1 x P09 gland |
| Connector, mating part | ALTW RCP-00BMMS-SLM7001 |
| Power Options | PoE, PoE+ |
| Auxiliary DC power | 24V nom (16-48V), 13W max – on request |
CONSTRUCTION
| Dimensions (HxWxD) | 169 x 120 x 52 mm |
| Weight | 0.85 kg |
| Outer shell | Powder coated aluminum, black |
| Mounting bracket material | PET-G |
ENVIRONMENT
| Protocols | IPv4 (with DiffServ), SIP, TCP, UDP, HTTPS, TFTP, RTP, RTCP, SRTP, DHCP, SNMP, Vingtor-Stentofon CCoIP®, NTP |
| Ingress Protection (IP) Rating | IP-65, according to AS 60529:2004 (R2018) |
| Impact Protection (IK) Rating | IK-08, according to IEC 62262:2002 + AMD1:2021 |
| Operating & Storage Temperature Range | -40°C to 55°C |
| Relative Humidity | < 95% not condensing |
NETWORKING & PROTOCOLS
| Protocols | IPv4 (with DiffServ), SIP, TCP, UDP, HTTPS, TFTP, RTP, RTCP, SRTP, DHCP, SNMP, Vingtor-Stentofon CCoIP®, NTP |
| LAN Protocols | Power over Ethernet (IEEE 802.3 a-f), Power over Ethernet (IEEE 802.3at), Network Access Control (IEEE 802.1x) |
| Management and Operation | HTTP/HTTPS (Web configuration), DHCP and static IP. Remote automatic software upgrade. Centralized monitoring. |
| SIP Support | RFC 3261 (SIP base standard) RFC 3515 (SIP refer) RFC 2976 (SIP info), SIP using TLS, RFC 5630 SIPS URI scheme |
CERTIFICATIONS
| Dimensions (HxWxD) | 169 x 120 x 52 mm |
| Emissions | EN 60945:2002 |
| Immunity | EN 61000-6-2:2005, EN 61000-4-2:2009, EN 50130-4:2011, EN 61000-4-3:2006 Ed.3.1, EN 61000-4-6:2009 Ed.3.0 |
| Electrical Safety | AS/NZS 62368.1:2018 |